Skip to main content
Version status: In force | Document consolidation status: Assimilated law updated to reflect all known changes
This version in force from: 31 December 2020

Article 21 Choice of the monitoring methodology

1. For the monitoring of the emissions of an installation, the operator shall choose to apply either a calculation-based methodology or a measurement-based methodology, subject to specific provisions of this Regulation.

A calculation-based methodology shall consist in determining emissions from source streams based on activity data obtained by means of measurement systems and additional parameters from laboratory analyses or default values. The calculation-based methodology may be implemented through the standard methodology set out in Article 24 or the mass balance methodology set out in Article 25.

A measurement-based methodology shall consist in determining emissions from emission sources by means of continuous measurement of the concentration of the relevant greenhouse gas in the flue gas and of the flue gas flow, including the monitoring of CO2 transfers between installations where the CO2 concentration and the flow of the transferred gas are measured.

Where the calculation-based methodology is applied, the operator shall for each source stream define, in the monitoring plan, whether the standard methodology or the mass balance methodology is used, including the relevant tiers in accordance with Annex II.