Article 45 Missing data

1. Where a piece of measurement equipment within a CEMS is out of operation for more than five consecutive days in any calendar year, the operator shall inform the competent authority without undue delay and propose adequate measures to improve the quality of the CEMS in question.

2. Where a valid hour or shorter reference period in accordance with Article 44(1) of data cannot be provided for one or more parameters of the measurement-based methodology due to the equipment being out of control, out of range or out of operation, the operator shall determine values for substituting each missing hour of data.

3. Where a valid hour or shorter reference period of data cannot be provided for a parameter directly measured as concentration, the operator shall calculate a substitution value as the sum of an average concentration and twice the standard deviation associated with that average, using equation 4 in Annex VIII.

Where the reporting period is not applicable for determining such substitution values due to significant technical changes at the installation, the operator shall agree with the competent authority a representative timeframe for determining the average and standard deviation, where possible with a duration of one year.